HW2-15 Miniature Load Cell

Features And Uses

●Stainless steel
●Ultra-micro structure/Super micro structure
●Widely used in robot hand grip, cold and hot press pressure detection, button feel tester and other applications where the installation space is small
Overall dimension

range

ΦA

H

H1

5-30kg

1.5

7

6.3

50-100kg

3

technical parameter
Capacity

5-100kg

Accuracy class

1.0%F.S.

Rated output

0.8~1.5mV/V

Zero balance ±0.02 mV/V
Non-linearity ±1%F.S.
Hysteresis ±1%F.S.
Repeatability ±1%F.S.
Creep(30min) ±1%F.S.
Temp.effect on output

±1%F.S./10°C

Temp.effect on zero

±1%F.S./10°C

Input impedance

350±10Ω

Output impedance350

350±5Ω

Insulation ≥5000MΩ(50VDC)
Recommended excitation 2.5~5VDC
Maximum excitation 7VDC
Compensated temp. range -10~40°C
Operation temp. range -20~60°C
Safe overloadx 120%F.S.
Ultimate overload 150%F.S.
Cable size Φ2x2m

Portection class

IP65
Force direction
Wiring diagram